Here you can find technical solutions for your
PenMount Resistive products. For pricing and further
support, please contact us with [
penmount@seed.net.tw ] ; for more
information about the function and
specifications of PenMount , please check the
products page.
General Questions
-
How many operating systems does PenMount
support ?
-
The following is a list of operating
systems that PenMount supports, you can
download the appropriate drivers from
the [
Download ] page. If the operating
system you are using is not listed here,
please fill out the [Company
Profile and Inquiry Form ] & [
PenMount Driver Special Request Form
] and email to
[
penmount@seed.net.tw ], we will
contact you as soon as possible.
|
|
PM9000
(RS232) |
PM5000
(USB) |
PM6000
(RS232) |
PM6000
(USB) |
|
Windows 2K/ XP/ 2003/ 2008/
Vista/ 7 |
● |
● |
● |
● |
|
Windows XP/ Vista/ 7 64bit |
● |
● |
● |
● |
|
Windows XP Embedded
Windows Embedded Standard 2009 |
● |
● |
● |
● |
|
Windows NT |
● |
● |
|
|
|
Windows 98/ Me |
● |
● |
|
● |
|
Windows 95 |
● |
|
|
|
|
Windows 3.1 |
● |
|
|
|
|
Windows CE 4.2/ 5.0/ 6.0 |
● |
● |
● |
● |
|
Dos |
● |
|
● |
|
|
Ubuntu 6.06/ 6.10/ 7.04/ 7.10/
8.04/ 8.10/
9.04/
9.10/ 10.04/ 10.10/ 11.04 |
● |
● |
● |
● |
|
Debian 4.0/ 5.0 32 & 64bit/ 6.0 |
● |
● |
● |
● |
|
Debian 3.1 |
● |
|
|
|
|
Fedora 9/ 10/ 11/ 12/ 13 32 &
64bit/
14 32 & 64bit/ 15 32 & 64bit |
● |
● |
● |
● |
|
Fedora Core 4/ 5/ 6/ 7/ 8 |
● |
● |
● |
● |
|
Fedora Core 4_64bit |
● |
|
|
|
|
Fedora Core 3 |
● |
● |
● |
|
|
Fedora Core 2 |
|
|
● |
|
|
Slackware 12.0/ 12.1 |
● |
● |
● |
● |
|
Slackware 10.0 |
● |
|
|
|
|
Red
Hat 9.0 |
● |
● |
● |
|
|
Red
Hat 7.3/ 8.0 |
● |
● |
|
|
|
OpenSuse 10.1/ 10.2/ 10.3/
11/ 11.1/ 11.2/ 11.3 32 & 64bit/
11.4 |
● |
● |
● |
● |
|
Suse
10.0 |
● |
● |
● |
|
|
Suse
9.2/ 9.3 |
● |
● |
|
|
|
Suse
8.0/ 9.0/ 9.1 |
● |
|
|
|
|
Cent
OS 5.2/ 5.3/ 5.4/ 5.5 |
● |
● |
● |
● |
|
Linux XFree86 4.x.x |
● |
● |
|
|
|
Linux XFree86 3.3.6 |
● |
|
|
|
|
Linux For GPM |
● |
● |
● |
● |
|
QNX
6.4.1/ 6.5 |
● |
|
● |
● |
|
QNX
6.3.2 |
● |
|
● |
|
|
QNX
6.2 |
● |
|
● |
|
|
Android |
● |
|
● |
● |
-
Does PenMount 6000 USB has QNX 6.3 / 6.4
/ 6.5 support?
-
Why the USB mouse and the USB keyboard
can’t act, after I set up the PenMount USB
device under QNX according to the
instructions?
-
Since the system will load the settings
in input.${HOSTNAME} to drive the input
device, this file must be correctly set
or the USB mouse and keyboard won't
operate correctly. Please follow the
steps described in README file and make
sure that the following file is added in
input.${HOSTNAME}.
devi-hid mouse kbd touch
-
Does PenMount provide drivers that
support Microsoft Windows 7 ?
-
Yes!! The PenMount Windows Universal
Driver supports most Microsoft Windows
systems from Windows 2000, XP, 2003,
2008, Vista to 7.
-
How to make the PenMount touch function
work correctly ?
-
How many kinds of control ICs that
PenMount has ? What are their difference ?
-
There are 3 kinds of PenMount control
ICs, describes as below :
(1). PenMount 9000 : a RS-232 interface
touch panel control IC.
(2). PenMount 6000 : a RS-232 and USB
combo touch panel control IC.
(3). PenMount M1 : a RS-232 and USB
combo multi-touch
panel control IC.
(4). PenMount P1 : a RS-232 and USB
combo Projected Capacitive touch panel
control IC.
Remarks: for the time being, the
PenMount 5000/6000/9000 touch
controllers cannot support multi-touch,
even by updating to the latest device
drivers.
-
What are the difference between
PenMount control boards ?
-
There are three types of PenMount
control boards, the difference is
described below :
|
controller
model |
Supporting
interface |
Working
boudrate(RS-232) |
Supporting
touch panel |
PNP mode
(RS-232) |
|
RS-232 |
USB |
9600 |
19200 |
4 wire |
8 wire |
5 wire |
PNP |
non-PNP |
|
9000 |
PM9036CH-5 |
● |
|
|
● |
|
|
● |
● |
|
|
PM9036CH-8 |
● |
|
|
● |
● |
● |
|
● |
|
|
PM9026BH |
● |
|
|
● |
● |
● |
|
● |
|
|
6000 |
PM6300A-5 |
|
● |
|
|
|
|
● |
|
|
|
PM6300A-8 |
|
● |
|
|
● |
● |
|
|
|
|
PM6500A-5 |
● |
● |
|
● |
|
|
● |
● |
|
|
PM6500A-8 |
● |
● |
|
● |
● |
● |
|
● |
|
|
PM6200x |
● |
● |
● |
● |
● |
● |
● |
● |
● |
|
PM6202B |
● |
● |
● |
|
● |
|
● |
|
● |
|
M1 |
PM6250 |
● |
● |
|
● |
Multi-touch |
|
● |
PM6200x has the same screw hole position
as 3MTM EXII 7000、EXII 8000 以及
SC400、SC500、SC800 series. It also
provides a 4 -wire ZIF connector.
Remarks: for the time being, the
PenMount 5000/6000/9000 touch
controllers cannot support multi-touch,
even by updating to the latest device
drivers.
-
-
Can PenMount work on COM ports that don't
support PNP detection ?
-
Yes, under the WinCE and Linux O.S.,
PenMount RS-232 is Non-PNP mode; under
2000/ XP/ 2003/ 2008/ Vista/ 7 O.S.,
please download the driver after the
edition of PenMount Windows universal
driver V2.2.0.263 from the [
Download ] page, and please also
refer to the set-up of
Windows Question 6 Non-PNP mode.
-
What's the purpose of the LED on
PenMount control board for?
-
The LED lights on PenMount control board
is used to determine the working state
of the controller. Here are some
circumstances that user might find it
shining.
(1) If the controller and touch panel is
connected correctly, the LED will be
lighted when touching the panel, and
will fade on release.
(2) If the LED is always lighted even
when no one touch the panel, it may
suggest that :
A. Some objects
oppress the panel by mistake.
B. The pin
assignments between the touch panel and
controller is not correctly set.
C. The driver
hasn't been installed if using PenMount
6000 RS-232.
(3) If the LED is not lighted when
touching the panel, the possible causes
are :
A. There is no
power supply.
B. The PenMount
controller is not functioning.
C. The
connector is broken.
D. User has touched the wrong side
of the touch panel, or it's not working
properly.
-
What is the maximum working distance for
cable between the computer and the PenMount
control board ?
-
(1). For RS-232 cable, the maximum
distance is 12 M. You can extend the
distance by using a RS-232 serial
extender. If you need to setup the
extender for PenMount, here are some
information :
(A) . Protocol 19200 bauds, N81
(B) . control signals : RTS, RXD, TXD,
GND, DTR, DSR
Please note, however, when using RS-232
connections with long distance, the PNP
detection might not work properly. In
this case you might need to consider
using a extender that supports PNP
function, or using a non PNP driver for
your PenMount device. Please check out
the General Questions 5
for more information.
(2). For USB cables, the maximum
distance without a extender depends on
the controller and transfer speed of the
USB. PenMount 6000 USB controller
supports full speed mode, and the
maximum distance is 5M. PenMount 5000
USB controller supports low speed mode ,
and the distance is 3M. To extend the
distance, you can consider using a USB
hub or a extender.
-
How to use PenMount RS-232 Driver and
Serial Mouse Driver at the same time
under DOS ?
-
How to make beep sound work properly
when touching the panel?
-
What's the function of the switch on
PenMount control board ?
-
The switches on PenMount 9000 and 6000
control boards is used to set the baud
rate / PNP mode and touch panel type.
The details are listed in the table
below :
-
|
model |
PIN |
1 |
2 |
3 |
4 |
|
PM6200
|
ON |
4 / 8 wire |
PNP |
9600 bps |
|
|
OFF |
5 wire |
non-PNP |
19200 bps |
|
-
Please avoid
using sharp tools when adjusting the
switches. The force used should be in a
parallel way.
PM9026BH
: There is no switch on
PM9026BH, the specification is fixed to
19200bps / PNP mode / 4 or 8 wire only.
PM9036CH-5 : There is no switch on
PM9036CH-5, the specification is fixed to
19200bps / PNP mode / 5 wire only.
-
PM9036CH-8 : There is no switch on
PM9036CH-8, the specification is fixed to
19200bps / PNP mode / 4 or 8 wire only.
PM6202B : There is no switch on PM6202,
the specification is fixed to 9600bps /
Non-PNP mode / 4 or 5 wire only.
PM6300A-5 : There is no switch on
PM6300A-5, the specification is fixed to
5 wire only.
-
PM6300A-8 : There is no switch on
PM6300A-8, the specification is fixed to
4 or 8 wire only.
PM6500A-5 : There is no switch on
PM6500A-5, the specification is fixed to
19200bps / PNP mode / 5 wire only.
-
PM6500A-8 : There is no switch on
PM6500A-8, the specification is fixed to
19200bps / PNP mode / 4 or 8 wire only.
Please note that after changing the
switch settings, user must reset the
controller firmware ( by resupplying the
power ) to make it use the new settings.
-
How to use both the USB and RS-232
interface at the same time on the
PenMount 6500A / 6200x / 6202B control
board ?
-
Although PenMount 6500 / 6200C / 6202
provide both the USB and RS-232
interfaces, the operating system will
only recognize the USB device when they
are both connected to the computer. As a
result, user can only choose to use
either RS-232 or USB at one time.
-
-
How to make the cursor position correctly
?
-
Some touch panels has lost it's
linearity, therefore need calibration.
PenMount provides a calibration utility
that corrects the cursor position up to
4% after calibration. It is recommend
that using a stylus instead of finger
when running the calibration utility.
In most cases the cursor should position
correctly after applying the 9 point
calibration. If the cursor position is
still incorrect after applying the 25
point calibration, user might consider
replacing the touch panel, since it has
totally lost it's linearity.
-
Has the PenMount control board pass the
ESD testing ?
-
Yes! All of the PenMount control boards
have passed the ESD testing, a few
detail is described in the table below :
|
|
Air Discharge |
Contact
Discharge |
|
PM6300
PM6200
PM6202
PM6500 |
15KV |
8KV |
|
PM9036BH |
15KV |
8KV |
-
If the ESD issue exists in your
computer, please connect the screw hole
with ground.
-
-
Has the PenMount controller pass the RoHS
standard ?
-
What's included in the standard PenMount
controller package ?
-
Does PenMount provide the driver of WinPE?
-
The PenMount controller I use is PM9512,
how can I download the driver ?
-
PenMount9512 has been phased out, the
drivers support only 3.1/ 95/ 98/ Me/
NT/ 2000、Dos、Linux XFree86 3.3.3-3.3.6/
4.x.x, we will not develop new driver
any more, if you have the need of the
driver for the systems above, please
inquire by e-mail with the information
of [Company
Profile and Inquiry Form ] & [
PenMount Driver Special Request Form
].
Windows
-
What’s the difference for new PenMount
Windows Universal driver under the
installation of 2000/ XP/ 2003/ 2008/ Vista/ 7?
-
For PenMount Windows Universal drivers
after V2.2.0.283, the operating modes
are different according to the target
Windows system :
1. Under Windows 2000/XP/2003, the
PenMount device operates as a mouse
device. The PenMount monitor will
appear on the notification area of
taskbar after system starts up. it can
provide touch screen calibration, multi
monitor mapping, Draw test function,
mouse simulation function, right mouse
button function, edge compensation
function and automatic rotation
function.
2. Under the Windows XP Tablet PC
Edition/ 2008/ Vista / 7, the PenMount
devices operates as a touch digitizer
device. The PenMount Control Panel can
be launched by double click on it's
shortcut on Windows desktop, which
provides the calibration, edge
compensation, and Draw test function.
The other functions are provided by the
Windows system. The settings for press
and hold for right mouse button, double
click, flicks, hand writing recognitions
can all be found in the Windows Control
Panel.
-
Why it can’t act, after installing the
PenMount Windows Universal V2.2.0.283 driver
under Windows Server 2008?
-
Because under the Windows Server
2008,the PenMount device will operates
as touch digitizer by default. However,
touch digitizers can only work when an
extra feature called the “Desktop
Experience” is installed. The “Desktop
Experience” provides many Windows 7
features including the Aero theme and
tablet PC. You will need to install the
“Desktop Experience” feature in Windows
Server 2008 by yourself. If you don’t
want to install the touch digitizer
device, we suggest you to install
PenMount device in mouse simulation
mode.
-
What can I do when I want to install
PenMount as a mouse device under Windows XP
Tablet/ 2008/ Vista / 7?
-
(A) You may use the edition before ( and
include) PenMount Windows Universal
V2.2.0.263 for installation.
(B) If you use the PenMount Windows
Universal V2.2.0.283, please modify the
install.ini as below before
installation:
[Option]
TouchReport = 1
After modification, please save the
file, then start the installation
procedure, it can make the PenMount
device be driven as the mode of simulate
mouse.
-
How to disable or enable the PenMount
control board with commands?
-
Please download the devcon.exe of
Microsoft, the web- site is:
http://download.microsoft.com/download/1/1/f/11f7dd10-272d-4cd2-896f-9ce67f3e0240/devcon.exe!
Then please refer to the following
instructions:
PM9000 RS-232:
Devcon.exe disable SERENUM\DCO9000
(To disable the touch screen)
Devcon.exe enable SERENUM\DCO9000
(To enable the touch screen)
PM6000 RS-232:
Devcon.exe disable SERENUM\DCO6000
(To disable the touch screen)
Devcon.exe enable SERENUM\DCO6000
(To enable the touch screen)
PM6000 USB:
Devcon.exe disable
"HID\VID_14E1&PID_6000" (To disable
the touch screen)
Devcon.exe enable
"HID\VID_14E1&PID_6000" (To enable
the touch screen)
-
I am using products of Advantech or IEI,
such as: Advantech FPM 3175 Monitor,
Advantech PPC-154T Panel PC, Allen Bradley
Versa View. I cannot make the touch screen
work when re-installing the device driver,
and I cannot find the related devices in the
device manager either, how can I do then?
-
The PenMount touch controller you use is
operated in the Non- PNP way, after the
PenMount Windows Universal driver
V2.1.0.234, it can support Non-PNP
devices.
If you have totally no idea which COM
port that the PenMount controller
connects with, we suggest you to install
the V2.1.0.234, this driver will change
the settings of every COM port appears
in the system, so that they can support
PenMount Non- PNP device.
If you already know the COM port that
the PenMount controller connects with,
we suggest you to install the edition
after the V 2.1.0.263. The driver will
not change the settings of every COM
port, it will only change according to
the install.ini that you install under
the PenMount installation path. By
default it will setup COM1 and COM2. If
you are using other ports for PenMount
device connection, then we suggest you
to refer to the Windows
Question 6, to modify the file and
then conduct the installation again.
Remarks: Please uninstall the PenMount
device driver exists in the system
first, restart the system, then install
the device driver again with new
settings. Please restart the system
after the installation completes.
-
How to setup PenMount non-PnP RS-232
controllers in the PenMount Windows
Universal Driver?
-
The PenMount Windows Universal Driver
V2.1.0.234 or later supports non-PnP
RS-232 PenMount controllers. In
V2.1.0.234, it will automatically change
every COM port settings to allow it
detect PenMount devices on system start
up. In PenMount Universal Driver
V2.1.0.263 or later, user need to setup
the ports which will detect non-PnP
RS-232 PenMount controllers manually,
please modify the “Driver\install.ini”
as below, before you install the device
driver.
[Install]
ENUM = 1 ; This will allow the following
ENUM section to take effect.
[ENUM]
Total = 6 ; Set up the total COM port
number
COM5 = 1 ; Setup the ports that will
allow PenMount non-PnP device detection
, in this case , COM5.
-
Does PenMount provide a resistive
multiple touch solution?
-
Yes ! PenMount has provided a resistive
multiple touch solution on the Microsoft
Windows platform, including the latest
Microsoft Windows 7. This solution
includes the PenMount M1 touch
controller or the PM6250 control board
along with the AMT MF resistive touch
panel, which currently supports up to 12
touch zones. Our main purpose is to
provide a economic solution for multiple
touch, there for the conditionally
multiple touch support will not met the
requirements for Microsoft Windows Touch
Logo.
If you have this need, please
inquire by e-mail with the information
of [Company
Profile and Inquiry Form ] & [
PenMount Driver Special Request Form
].
Remarks: for the time being, the
PenMount 5000/6000/9000 touch
controllers cannot support multi-touch,
even by updating to the latest device
drivers.
-
What is the difference between Windows 7
and Vista in touch input?
-
A. Windows 7 supports multi-touch input
devices, and provides API for two finger
gestures. Windows Vista only supports
single touch input device.
B. On both Windows Vista and Windows 7,
user will be able to use the Tablet PC
features after installing the PenMount
Universal Driver V2.2.0.283.
C. Windows 7 provides additional Tablet
PC features, including the multiple
monitor mapping for touch digitizer
devices. In Windows Vista, all touch
digitizers can only map to the primary
display.
Remarks: For the time being PenMount
5000 /6000 / 9000 don’t support multi
touch, and the 2 points touch function
can’t be realized by updating the driver
either.
-
What does “gesture” and “flicks” mean?
-
Does PenMount support single-finger
gestures?
-
Yes, PenMount has developed the
gestures, after the PenMount Windows
Universal driver V2.1.0.263 edition,
they all support the single touch
gesture.
-
Why can't I use the tablet PC features in
Windows Vista / 7 after I install the
driver?
-
The driver you install is the edition
before PenMount standard Windows
Universal Driver V2.1.0.263, this is the
driver that simulates the mouse device.
If you need to use the Tablet PC
function of the Windows Vista or Windows
7, please download the newest edition
PenMount Windows Universal Driver
V2.2.0.283, this driver supports all
series of PenMount control boards, when
install under the Windows XP Tablet/
Vista/ 7, it works as touch digitizer
device, and then all the build-in
features of Tablet PC can be used!
-
How to update the driver downloaded from
website ?
-
If you are going to install PenMount
Universal Driver V2.0.0.113, please
follow the steps below to install the
driver :
Download the appropriate PenMount
Windows universal driver matching your
operating system.
Uninstall the old PenMount Windows
universal driver.
Make sure that the PenMount controller
has been connected to the computer.
Restart the Windows system.
Install the new PenMount Windows
universal driver.
Restart the Windows system.
If you are going to install PenMount
Windows Universal Driver V2.0.0.187 or
newer, please follow the steps below to
install the driver :
Download the appropriate PenMount
Windows Universal Driver matching your
operating system.
Uninstall the old PenMount Windows
Universal Driver.
Restart the Windows system.
Install the new PenMount Windows
Universal Driver.
Restart the Windows system.
If you connect other PenMount
controllers and do not see them in the
PenMount Control Panel, please press the
“Update” button in the PenMount Control
Panel, and wait for the device scanning
finishes.
* Please do not
install or update driver from the device
manager, run setup.exe instead
-
Why doesn't the touch function work after
installing the PenMount Windows universal
driver ?
-
Please follow the check lists below :
(1). Uninstall the driver,
make sure that the PenMount control
board is connected to the computer, then
restart Windows.
(2). Make sure that the
driver matches the PenMount control
board and operating system you are
using.
If the device of PenMount is RS-232
interface and works in Non-PNP mode,
please make sure that the RS-232 cable
is connected to the computer first, then
follow the Windows
Question 6 to install, and continue
to do the step 5
(3). Check if there is an
unknown device or HID-compliant mouse
under the [ Mice and other pointing
devices ] group in the [ Device Manager
].
(4). If no device is found
in step (3), please check if the
connector near the PenMount control
board is loosed, and whether the COM /
USB port is working correctly.
(5). Reinstall the PenMount
Windows universal driver.
If the touch function still fails after
doing the previous checks, please fill
out the [Company
Profile and Inquiry Form ] & [
PenMount Driver Special Request Form
] and email to [
penmount@seed.net.tw ]. We will help
you solve the problem as soon as
possible.
-
Why is the touch panel working with wrong
direction after plugging the PenMount USB
control board, and no device is shown in the
PenMount Control Panel ?
-
How to completely remove the PenMount
Windows universal driver, and prevent the
system from installing the driver again
after restarting Windows ?
-
Has the PenMount Windows universal
driver pass the Microsoft WHQL
certification ?
-
How to adjust the double tap speed in
Windows ?
-
For PenMount Windows Universal Driver
before V2.1.0.263, please change the
“Double click speed” of mouse, which can
be found in the control panel.
For PenMount Windows Universal Driver
after V2.2.0.283, under Windows 2000 &
XP( PenMount controller is mouse
device), please change the “Double click
speed” of mouse, which can be found in
the control panel. And under Windows
Vista & 7(PenMount controller is touch
digitizer device), please go to the
control panel, launch “Pen and Input
Devices” in Windows Vista, or “Pen and
Touch” in Windows 7, then change the
“Double-tap ” settings in the “Touch”
tab ( Do not change the one in “Pen
Options” tab by mistake ).
-
Does the PenMount Windows Universal
Driver support screen rotation ?
-
Under Windows 2000/ XP/ 2003, PenMount
Windows Universal Driver supports
display rotation function of Intel,
Nvidia, ATI, SMI, Via, and the Pivot
rotation software by Portrait company;
It can rotate 90o、180o、270o, under the
Windows Vista/7, because it’ s the
Digitizer that be installed, as long as
they are the inner established Windows
Pen Input device functions of the
Windows Vista/ 7, they all can be
supported. It includes the rotation of
the screen, multi- screen functions,
long press of the right key, flicks
gestures…
-
How to wake up the Windows XP system by
touching the panel in suspend mode ?
-
The touch wakeup function only works
under several condition.
(1). When using the RS-232
interface, it only supports wake up from
S1 mode.
When using the USB interface, if the
BIOS supports “USB device wake up from
S3” and there is power supply for
PenMount during suspend, user can wake
up the system by the touching.
-
Why does the touch function fail when no
mouse is attached to the system under
Windows 2000 / XP ?
-
The problem can occur on PenMount 9000
controllers, which is caused by the
compatibility issues of BIOS and
Windows. User can change the switch
settings to non PNP mode, then install
the non PNP Windows driver. The non PNP
driver can be found in the [
Download ] page.
-
Why does the touch function failed when
changing port of the PenMount USB device ?
-
Why does the cursor position and movement
direction is still incorrect after
installing the driver ?
-
Calibration is needed if it's the first
time installing PenMount driver. The
calibration utility provides two modes :
standard calibration and advanced
calibration. The advanced calibration is
used to correct the non linearity ( up
to 4% ) of touch panels. If the cursor
still positions incorrectly after
calibration , we suggest that user
should replace the the touch panel,
since it has totally lost it's
linearity.
-
How to call the calibration utility
outside the PenMount Control Panel ?
-
User can call the calibration utility
when using newer PenMount drivers.
(1) Supported
driver version
(a) PenMount 9000 Driver V5.0 or after.
(b) PenMount 5000 Driver V4.1.0005 or
after.
(c) PenMount Universal Driver.
(2) Syntax
<Path To Install Dir>\DmcCtrl.exe
-calibration [ 0 | 4 | 9 | 16 | 25 ]
In this case , 0 is for standard
calibration , and 4, 9,16,25 is for
advanced calibration.
-
How to use multiple touch panel at the
same time ?
-
PenMount can support up to 6 touch
controller mapped to different display
monitors at the same time, with the
following condition :
1.
Please use Windows 2000/ XP/ 7. (
Windows Vista doesn’t support )
2.
Update the device drivers to the latest,
which is PenMount Windows Universal
Driver V2.2.0.283.
3.
The USB controllers should be plugged in
different ports of the USB Hub. It is
not supported with the extension of same
port.
4.
All touch controllers must be the
PenMount controller.
To launch the monitor mapping program,
follow the steps below.
On Windows 2000 / XP:
(A). In PenMount Control Panel, change
to the “Multiple Monitors” tab.
(B). Check the “Multiple Monitor
Support” box.
(C). Press the “Map Touch Screens”
button.
(D). Follow the steps shown on screen
and finish the mapping process.
(E). When monitor settings has been
changed, please run the monitor mapping
program again.
On Windows 7:
(A). Please use clone mode and finish
calibration for all PenMount touch
controller.
(B). Please set monitor in the mode that you want.
(C). Launch the “Tablet PC Settings” in
the control panel
(D). Click on the “Setup...” button
beside the “Configure your pen and touch
displays” label
(E). Follow the descriptions on the
screen to finish the monitor mapping.
-
How to install another PenMount device if
the PenMount driver has already been
installed in the system ?
-
There are two ways for new device
installation, depending on the driver
version user is using.
(1). If the driver installed is not
PenMount Windows Universal Driver, or
the universal driver version is earlier
than 2.0.0.113, user must first move the
existing PenMount driver then reinstall
it for new device installation. Please
refer to the Windows
Question 10 for updating the driver.
(2). Since PenMount Windows Universal
Driver version 2.0.0.187, a device
refreshing function is added to the
PenMount Control Panel. Please make sure
that all PenMount devices are connected
to the system correctly before running
the refresh function. Please visit the [
Download ] page for the latest
PenMount Windows Universal Driver.
-
Why does the touch function fail when
changing to a different model of PenMount
control board even after installing the
PenMount Windows Universal Driver ? Doesn't
it support all PenMount controller model ?
-
Yes! PenMount Windows Universal Driver
does support all the PenMount controller
model. However, for older version of
PenMount Windows Universal Driver, user
should uninstall the driver and restart
Windows first, then install the driver
again, since it only installs driver for
new devices at the installation process.
For PenMount Windows Universal Driver
V2.1 and later, a device refreshing
function is added to the PenMount
Control Panel, so it can detect
and install the device driver directly
without reinstalling.
-
Does the PenMount controller
automatically maps to the correct area
when changing the extended desktop
settings for multi-monitors ?
-
How to do the screen mapping when there
are multiple monitors but only one with
touch panel.
-
(A) On Windows 2000 / XP, please refer
to Windows Question 22
for multi-monitor setup instructions
first. Please press “s” to skip the
mapping when PenMount Control Panel
prompts to map the monitors without
touch panel.
(B). On Windows 7, If the touch screen
is mapped to monitors other than the
primary display, please follow the
descriptions in Windows
Question 22 to set up the correct
mapping.
-
Can the multiple monitor function work
when using different models of PenMount
controller ?
-
Can the multi-monitor function work when
combining PenMount with other brands of
touch controllers ?
-
What is the difference between the
Windows CE driver that marked “stylus” and
the standard driver ?
-
Can it support two PenMount devices under
WinCE ?
-
After using PenMount WinCE stylus driver,
I can’t see the Microsoft’s calibration on
the control panel. What should I do ?
-
Please add the "BSP_NOTOUCH = 0” into
the Environment of the Platform Builder,
when you finish setting up the WinCE
system, there will be the inner
established calibration of the Microsoft
on the control panel.
-
Why is the cursor position becomes
incorrect after restarting Windows CE system
?
-
Why does the PenMount USB Windows CE
Driver fail to work ?
-
1. In WinCE 4.0/ 4.1/ 4.2, this can be
caused by the USB controller settings.
USB 1.1 has two kinds of interfaces :
OHCI and UHCI, please make sure which
kind of interface that system is using.
If a USB mouse don't work on Windows CE
system, that means that there is
something wrong in the OHCI or UHCI
setting. In Windows CE 5.0 / 6.0 do not
have to set up the USB interface. If not
under normal operation, please double
check the USB connection !
2. Please notice that if you are using
PenMount 6000 USB with firmware
6000.6.0.0 or later, you will need to
use the PenMount 6000 USB Windows CE 4.2
V1.2 / 5.0 / 6.0 V3.0 driver or later to
work properly.
3. If you are using PenMount 6000
firmware 6000.6.0.0, but you have
already built the system image with
older PenMount USB device drivers,
including PenMount WinCE4.2 device
driver V1.1 or PenMount WinCE 5.0/6.0
device driver V3.0 or older, you can
still make the touch screen working by
following the steps below:
(1) Add new registry key
[HKEY_LOCAL_MACHINE\Drivers\USB\LoadClients\5345_24576\Default\3\PenMount_USB_HID_Class_Driver]
(2) Copy all registry values under
[HKEY_LOCAL_MACHINE\Drivers\USB\LoadClients\5345_24576\Default\3_1_2\PenMount_USB_HID_Class_Driver]
to (1)
without deleting the original registry
key.
(3) Save the registry
(4) Restart the system
4. When using PenMount device driver
V3.2 or older, the mouse cursor might
stick to the center of the screen when
using a brand new PenMount control board
or IC. This is due to no calibration
data stored in the PenMount control IC.
To solve this issue, please use other
input devices like mouse or keyboard to
launch the PenMount calibration program.
After finishing the calibration, the
touch screen will be back to normal.
This problem has been fixed in the
latest PenMount device driver for
Windows CE 5.0 / 6.0 V3.3. The cursor
will not be blocked in the center of the
screen any more.
-
How to set up if only use for four point
to position?
-
This function only supports in PenMount
WinCE Standard driver V3.0 or later,
please refer to Readme.txt in "Driver"
folder.
(Please modify PMSer.reg file in
"Driver" folder with RS-232 interface,
in case of USB interface please modify
PM2Usb.reg file. Stylus uses MS embedded
position software, so it is not
supported)
[HKEY_LOCAL_MACHINE\Software\PenMount\Calibrate]
"NoCal16"=dword:0 ====> When setting
to 0, function with standard calibration
and advanced 9
and 16 points calibration
"NoCal16"=dword:1 ====> When
setting to 1, function with standard
calibration and advanced 9
points calibration, without 16 points
calibration
"DefaultCalib"=dword:9 ====> When
setting to 9, after the open position
will not allow users to
choose calibration points, will direct
the user of advanced 9!
0 stands for standard calibration, 4
stands for 4 points advanced
calibration,
9 stands for 9 points advanced
calibration, 16 stands for 16 points
advanced calibration
.
-
When I use PenMount Serial WinCE driver
with PM6000 RS-232 or PM9000 controller, why
does the touch sometimes fails after system
starts up ?
-
Please adjust the controller switch into
non-PNP device, since all Penmount
RS-232 controller device all be Non-PNP
in Windows CE. Normally the RTS signal
of RS-232 is not used, however sometimes
the operating system send RTS signal to
PenMount controller, resulting in the
controller does not work after Windows
CE starts up !
-
How should I check if the PenMount Device
Driver will be built into system in the
Windows CE 6.0 Platform Builder ?
-
How to resolve the error that appears when
building system image after the PenMount
WinCE 6.0 Device Driver is selected ?
-
I install PenMount RS-232 on COM port, and
follow the ReadMe.txt of PenMount WinCE
driver to install the driver, but it still
doesn’t work, how can I do ?
-
Under WinCE, the pre- setting will
recognize the hardware COM1 as debug
port, the correspondences between
systems and hardware COM ports are as
below:
Hardware Systems
PenMount driver REG setting
COM1 -----> debug port ----->
COM2 -----> COM1
-----> "Port"=dword:1
COM3 -----> COM2
-----> "Port"=dword:2
COM4 -----> COM3
-----> "Port"=dword:3
:
:
:
Please set your COM port as the
description above; if you want to
relieve the debug mode of COM1, please
refer to the steps below:
A. change the platform.reg and search
the sections below:
IF BSP_NOSERIAL !
[HKEY_LOCAL_MACHINE\Drivers\BuiltIn\Serial]
"SysIntr"=dword:13 ; "SysIntr"=dword:13
is the setting of IRQ,13 represents IRQ
3
"IoBase"=dword:02F8 ; "IoBase"=dword:02F8
is the setting of IO Port = 2F8
change them into:
IF BSP_NOSERIAL !
[HKEY_LOCAL_MACHINE\Drivers\BuiltIn\Serial]
"SysIntr"=dword:14 ; is the
setting of IRQ,14 represents IRQ 4
"IoBase"=dword:03F8 ; is the
setting of IO Port = 3F8
After finishing the settings above,
please re- build the whole Platform, the
COM1 will be the COM1 that system
recognizes.
B. If PenMount RS-232 device still can’t
work after your settings as above,
please test it by the following steps:
1. Remove the PenMount RS-232 device,
install the RS- 232 mouse to the same
COM port, and test if the COM port works
normally in WinCE.
2. If your system is x86 platform,
please test it by XP to see if the
hardware works normally.
If the descriptions can’t resolve your
problems, please contact with us by
e-mail with the information of [Company
Profile and Inquiry Form ] & [
PenMount Driver Special Request Form
].
-
After I use PenMount WinCE USB Driver,
touch works normally, but USB mouse and
keyboard works abnormally, sometimes it
can’t boot, sometimes USB mouse and keyboard
works normally after booting, but they can’t
act after plugging and pulling, what is this
problem ?
-
For clarifying the cause of this
problem, after removing the PenMount
WinCE USB driver from WinCE platform
builder, please set a WinCE system
without PenMount driver, and compare
this system with the system includes
PenMount driver, thus you may find out
if this problem is related with PenMount
WinCE USB driver. PenMount team has
handled similar problem like this, and
we found that the cause is the
incompatibility between USB chip and
WinCE. Just for your reference.
-
Does PenMount Windows driver supports
Windows XP Embedded ?
-
Yes ! The PenMount device driver can
support Windows Embedded systems base on
the Windows XP kernel, includes Windows
XP Embedded and the Windows Embedded
Standard 2009. There are two ways to
install the driver :
(1). Build the Windows XP Embedded
system with PenMount driver. The
specific driver can be found in the [
Download ] page. Please note,
however, with this method user will not
be able to uninstall the PenMount driver
later.
(2) .Install the standard PenMount
Windows driver on Windows XP Embedded
system.
-
When I install PenMount Windows universal
Driver in Windows Embedded system, the
search driver window pop up, how to solve
this?
-
PenMount Windows universal Driver
depends on Windows HID driver. Please
add Windows HID components into XPE
system when building the XPE system.
When you install PenMount Windows
universal driver, the system will search
HID driver. You can find the file in
\Windows\system32 and
\Windows\system32\drivers, and PenMount
Windows universal driver will be
installed successfully.
-
Why does the same driver's beep function
works on Windows XP , but fail on Windows XP
Embedded.
-
Does PenMount supports tablet PC
applications ?
-
Yes! If you are using Windows XP Tablet
PC Edition 2005 / Windows Vista or
Windows 7, you will be able to use the
tablet PC features, such as press and
hold for right mouse button, hand
writing, and flicks, by installing the
PenMount Windows Universal Driver
V2.2.0.283 or later.
Linux
-
There is no X window in my Linux system.
Does PenMount provide the kernel driver in
Linux system?
-
After installing PenMount USB driver in
Linux, touch works normally, so does
calibration, but after pulling it out and
plug it in the same or another USB port, the
cursor is not accurate while touching, it
can’t be calibrated normally either, how can
I resolve this problem?
-
To pull out and plug in PenMount USB
device, or to change the USB port,
meanwhile the touch works, it’s not
because of PenMount driver device, but
because of the Linux inbox HID driver
which drives PenMount USB device,
therefore the touch is not accurate,
PenMount calibration can’t be used
either. Linux supports completely hot
plug only after the version X window
1.5. It supports this hot plug function
if you work with the version after
PenMount Linux driver V3.6.1.
-
After install PenMount Ubuntu 10.04 driver
V3.0.1, it is some problems in the
calibration function. How do I solve the
problems?
-
Why does the old settings in /etc/xorg.conf
disappears after I install the PenMount
Device Driver ? How do I get those settings
back ?
-
The PenMount Linux device driver
V2.3.0.15 and V2.4.1 will first backup
/etc/X11/xorg.conf during installation,
and then overwrites it with the one that
includes PenMount specific settings, to
ensure that the touch screen can be
operate correctly. If you have other
settings in the original /etc/X11/xorg.conf,
you will need to copy them manually back
to the /etc/X11/xorg.conf. The back up
of xorg.conf can also be found in
/etc/X11/ with its original name
concatenate with current date and time.
-
Why does the PenMount still not working
after installing the PenMount Linux Driver.
-
Please check the following lists first.
If it is still not working, please fill
out the [Company
Profile and Inquiry Form ] & [
PenMount Driver Special Request Form
] along with the
configuration file ( xorg.conf ) and the
log file ( Xorg.0.log ) , then send to [
penmount@seed.net.tw ] . Our
customer service will provide you a best
solution as soon as possible.
(1). The PenMount Linux Driver matches
the version of the Linux system (
kernel, X Windows System version )
(2). Read the readme file, and follow
the steps to install the driver.
(3). Beware that it's case sensitive
under Linux system, so don't mistype
anything.
(4). Make sure that the COM and USB port
settings are correct.
-
How to make the PenMount Linux driver
work under X Window System ?
-
If the system is running Xfree86, please
modify the xf86config file; if the
system is using Xorg, please modify the
xorg.conf file. Please follow the sample
settings in readme and modify the file,
but beware that wrong settings might
make the X Window crash. If you are
having problem setting up the PenMount
Linux driver, please fill out the [Company
Profile and Inquiry Form ] & [
PenMount Driver Special Request Form
] and email to
[
penmount@seed.net.tw ]. Our customer
service will provide you a best solution
as soon as possible.
-
How to use the PenMount touch function in
the text mode of Linux system ?
-
Can the PenMount Linux driver support
screen rotation ?
-
Does the PenMount Linux driver support
the emulation of mouse and button function ?
-
Why does the cursor position incorrectly
after installing the PenMount Linux driver ?
-
Why does the PenMount RS-232 controller
fail to work on COM3, but work well on COM1
and COM2 ?
-
Please do the following checking :
(1). Does the IRQ / IO address of COM3
conflict with other ports ?
(2). Does the COM port work correctly
with other devices such as serial mouse
?
(3). Has the COM port already been
occupied by other devices ?
(4). Most Linux system has wrong
settings for COM3 and COM4, and user may
need to make kernel again after changing
the settings. Please refer to other
Linux documents for detail.
For further support, please
download the [Company
Profile and Inquiry Form ] & [
PenMount Driver Special Request Form
] and email to [
penmount@seed.net.tw ]. Our customer
service will provide you a best solution
as soon as possible.
-
Why does the PenMount USB controller
fails after changing the USB port ?
-
Why does the calibration utility causing
a segmentation fault each time it is
executed ?
|